GENERAL FEATURES

  • High resolution LCD display, 7.0 inches.
  • Multi-reading feature allows auto-read, timed-read and continuous-read.
  • Automatic/Manual temperature compensation ensures accurate results.
  • Auto-hold feature senses and locks the measurement endpoint.
  • Data Storage 500 sets of each parameter(GLP-compliant).
  • RS-232 communication for print.
  • USB communication for PC software
  • Reset feature automatically resumes all settings back to factory default options.
  • IP54 waterproof.
pH
  • 1-5 points calibration with Standard Recognition.
  • Selectable pH buffer groups, including NIST, DIN, GB, USA and GOST.
  • Automatic electrode diagnosis with pH slope and offset display.

Ion

  • 1-5 points calibration with polyline fitting or linear fitting.
  • Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm and ppb.²
  • Direct Reading mode.
  • Over 10 methods are built-in, including F, Cl, I, NO3, BF4, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Agand NH3-N. User-defined method is supported.

Conductivity

  • 1-3 points calibration with Standard Recognition.
  • Settable parameters, including cell constant, temperature compensation coefficient and TDS factor.
  • Temperature compensation type (none, linear, pure water).

Includes

  • E-301-QC 3 in 1 pH composite electrode
  • DJS-1VTC Conductivity Electrode
  • pH standard solution(4.01, 7.00, 10.01) , 50mL/vial
  • 1413μS/cm EC standard solution, 50mL, 1 vial
  • REX-5 electrode stand
Specifications
Model M3F-A
Parameters pH/EC/ISE/Temp. (mV/pX/Resistivity/TDS/Sal.)
pH Range -2.00~20.00 pH
Resolution 0.1, 0.01 pH
Accuracy ±0.01 pH
Calibration Points Up to 5
Standard Customization Yes
Standard Recognition NIST, DIN, GB, USA and GOST buffers
Slope Limit Yes
mV Range -2000.0~ 2000.0 mV
Resolution 0.1 mV
Accuracy ±0.3 mV or ±0.1%
pX Range -2.00~20.00 pX
Resolution 0.1, 0.01 pX
Accuracy ±0.01 pX
Calibration Points Up to 5
ISE Range 1.000e-9 to 9.999e+9
Unit mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
Resolution Up to 4 significant digits
Accuracy ±0.5%
Calibration Points Up to 5
Conductivity Range 0.000 μS/cm~1000 mS/cm
Resolution 0.001 μS/cm minimum,

various with range selection

Accuracy ±1.0% FS
Reference Temperature 20, 25ºC
Calibration Points Up to 3
Standard Recognition 84μS/cm, 1413μS/cm, 12.88mS/cm
Resistivity Range 5.00 Ω·cm~20.00 MΩ·cm
Resolution 0.01 Ω·cm minimum
Accuracy ±1.0% FS
TDS Range 0.00 ppm~300 ppt
Resolution 0.01ppm minimum, various with range selection
Accuracy ±1.0% FS
Salinity Range 0.0~80.0 ppt, 0.00~8.00 %NaCl
Resolution 0.1ppt, 0.1%
Accuracy ±2ppt
Temperature Range (-5~110)ºC, (23~230)ºF
Unit ºC,ºF
Resolution 0.1
Accuracy ±0.2ºC
Measurement Reading Mode Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts Reading, Stable, Locked
Temp. Compensation ATC, MTC
Data management Data Storage 500 results each
GLP Features Yes
Inputs pH Electrode BNC(Q9)
DO with Temp. Probe 4-pin aviation connector
Conductivity with Temp. Probe 5-pin aviation connector
Outputs USB PC
RS 232 printer
Display options Backlight Yes
Auto Shutdown 1~60 min, off
IP Rating IP54
Date and Time Yes
General Power EU Power Adapter (Input: AC 230V/50Hz; Output: DC 20V/1000mA). Configurable power adapter option available.
Dimensions 242×195×68 mm
Net Weight 900g (1.98 lb)
Dimensions (Carton) 370×305×330 mm